Florida Approvals
Single Slope, Ridge, Pyramid, and Polygon Configurations


Approval Numbers
Large
Missile
Impact
Small
Missile
Impact


HVHZ

Non-
HVHZ
Design
Pressure
(pounds)
Maximum
Daylight
Opening


Glazing
FL12644 12644.1 Yes Yes +70 / -90 52.50 x 82.75 Laminated
12644.2 Yes Yes +70 / -70 52.50 x 82.75 Laminated
12644.3 Yes Yes Yes +70 / -90 52.50 x 82.75 Laminated
12644.4 Yes Yes Yes +70 / -70 52.50 x 82.75 Laminated
FL13277-R1 13277.1 Yes Yes +90 / -90 57.38 x 82.38 Insulated
13277.2 Yes Yes Yes +90 / -90 57.38 x 82.38 Insulated
13277.3 Yes Yes +75.4 / -75.4 57.38 x 82.38 Insulated
13277.4 Yes Yes Yes +75.4 / -75.4 57.38 x 82.38 Insulated
FL13370-R1 13370.1 Yes Yes +75.4 / -75.4 58.62 x 82.62 Insulated
13370.2 Yes Yes Yes +75.4 / -75.4 58.62 x 82.62 Insulated
TRU-ARC Barrel Vault Configurations


Approval Numbers
Large
Missile
Impact
Small
Missile
Impact


HVHZ

Non-
HVHZ
Design
Pressure
(pounds)
Maximum
Daylight
Opening


Glazing
FL12317 12317.1 Yes Yes Yes +50 / -50 54.00 x 30.56 Insulated

Miami-Dade Approvals
Single Slope, Ridge, Pyramid, Polygon, and Barrel Vault Configurations

Approval
Numbers*
Large
Missile
Impact
Small
Missile
Impact


HVHZ
Design
Pressure
(pounds)
Maximum
Daylight
Opening


Glazing
NOA 10-0426.12 Yes Yes up to +75.4 / -75.4** up to 58.62 x 82.62** Insulated or Laminated**
NOA 10-0426.13 Yes Yes up to +75.4 / -75.4** up to 58.62 x 82.62** Insulated or Laminated**
*Final approval
**Varies according to application

Hurricane Testing Documentation
Single Slope, Ridge, Pyramid, and Polygon Configurations

Test
Report

Report
Date
Large
Missile
Impact
Small
Missile
Impact

Test
Conducted

Test
Description
CTLA 1642W
 
04-12-07
 
Yes
 
ASTM E1996-02
ASTM E1886-02
. . . Performance of . . . Exterior Windows . . . Impacted by Windborne Debris in Hurricanes
. . . Performance of . . . Exterior Windows . . . Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials
TEL 01690152
 
 
 
 
08-22-09
 
 
 
 
N/A
 
 
 
 
N/A
 
 
 
 
AAMA/WDMA/CSA 101/I.S.2/A440-05
ASTM E283-04
ASTM E547-00
ASTM E330-02
ASTM E330-02
AAMA/WDMA/CSA 101/I.S.2/A440-05 Standard/Specification for Windows, Doors and Unit Skylights
Air Leakage Resistance
Water Penetration Resistance
Uniform Load Deflection Test
Uniform Load Structural Test
TEL 01690151
 
 
 
 
08-22-09
 
 
 
 
 
 
 
 
 
Yes
 
 
 
 
TAS 202-94 & TAS 201/203-94
ASTM E283-04
ASTM E547-00
ASTM E330-02
ASTM E330-02
High Velocity Hurricane Zone Protocols TAS 202-94, TAS 201-94 and TAS 203-94
Air Leakage Resistance
Water Penetration Resistance
Uniform Load Deflection Test
Uniform Load Structural Test
TEL 01690152-IC
 
08-22-09
 
 
 
Yes
 
ASTM E 1886-05
ASTM E 1996-05
. . . Performance of . . . Exterior Windows . . . Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials
. . . Performance of . . . Exterior Windows . . . Impacted by Windborne Debris in Hurricanes
TEL 01690235
 
 
 
 
02-02-10
 
 
 
 
N/A
 
 
 
 
N/A
 
 
 
 
AAMA/WDMA 101/I.S.2/A440-05
ASTM E283-04
ASTM E547-00
ASTM E330-02
ASTM E330-02
AAMA/WDMA 101/I.S.2/A440-05 Standard/Specification for Windows, Doors and Unit Skylights
Air Leakage Resistance
Water Penetration Resistance
Uniform Load Deflection Test
Uniform Load Structural Test
TEL 01690235-IC 08-03-10 Yes Yes ASTM E1886/1996-05 Large Missile Impact and Small Missile Impact
TEL 01690272 08-03-10 Yes Yes TAS 201-94, TAS 203-94 High Velocity Hurricane Zone Protocols TAS 201-94 and TAS 203-94 Large Missile Impact and Small Missile Impact
TRU-ARC Barrel Vault Configurations

Test
Report

Report
Date
Large
Missile
Impact
Small
Missile
Impact

Test
Conducted

Test
Description
CTLA 1642W-1
 
04-12-07
 
Yes
 
 
 
ASTM E1996-02
ASTM E1886-02
. . . Performance of . . . Exterior Windows . . . Impacted by Windborne Debris in Hurricanes
. . . Performance of . . . Exterior Windows . . . Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials
CTLA 1642W-2
 
 
 
 
04-12-07
 
 
 
 
N/A
 
 
 
 
N/A
 
 
 
 
AAMA/NWWDA 101/I.S.2-97
ASTM E283-99
ASTM E547-00
ASTM E331-00
ASTM E330-02
Voluntary Specification for Aluminum, Vinyl (PVC) wood Windows and Glass Doors
Air Infiltration
. . . Test Method for Water Penetration . . . by Cyclic Static Air Pressure Difference
. . . Test Method for Water Penetration . . . by Uniform Static Air Pressure Difference
Uniform Load Structural
CTLA 1642W-3 04-12-07 Yes   TAS-201, TAS-202 & TAS-203 TAS-201 (Large Missile), TAS-202 & TAS-203
Gammans Skylight Systems ©2014              770-254-1992              10 Beavers St, Newnan GA              
low-e skylight photo hi performance glass canopy skylight metal framed skylights custom skylight greenhouse commercial skylight retail high performance glazing environment barrel vault skylight sloped roof structural skylights polygon skylight glazing lite solarium enclosure translucent Tru-Arc insulated renovation lighting Gammans Skylight Systems structural skylight commercial skylights sloped glazing conservatory roof glass slope skylight manufacturer sloped glass custom skylights hipped ridge commercial rafter aluminum hurricane tested skylights pyramid skylight laminated round skylights 08630 sun light sun moon light glass skylight ridge efficient pyramids photos of skylights Dow 795 contractor insulated glass skylight HVHZ sunrooms daylight skylight installation Dow 995 remodeling Hurricane tested skylight polygon solariums metal framed skylight skylight natural light circular skylight roof window energy hipped high performance glass sky Dow Corning 995 flashings ridge skylight tempered HTP aluminum frame atrium barrelvault Lite-Rail architectural single slope skylight high performance sealant curb mount skylight skylights natural lighting solar hi performance glazing pyramid skylight photos Dow Corning 795 custom